ZTVK's butterfly valve for chilled water system is a wafer-type, quarter-turn valve designed for HVAC cooling loops, chiller distribution piping, and closed-loop water systems. Available in sizes from DN40 to DN1200 (1.5" to 48") rated PN10/PN16 and certified for 0°C to 80°C usage it is suitable for water, treated glycol mixes, gas and oil. Each unit is CNC machined and spherical disk polished to provide continuous sealing contact over long service cycles, with low operating torque and minimum seat wear over the life of the valve.
Chilled water systems run constantly between 4 °C and 12 °C. This range results in condensation and thermal contraction and persistent mechanical stress on sealing surfaces.
The disk is one piece and employs spherical surface processing, the disk edge is manually polished. This method ensures uniform sealing contact to the repeated open/close cycles and reduces the operating torque and improves the service life of the seat in continuous-duty HVAC systems.
The disc-and-stem thin-plate design provides a higher flow coefficient (Cv) than the standard spindle-through designs. The decreased cross-section leads to lower pressure drop across the valve supporting greater chiller energy performance around the loop.

|
Parameter |
Details |
|
Size Range |
DN40–DN1200 (1.5"–48") |
|
Working Pressure |
PN10 / PN16 |
|
Connection Method |
Wafer Type |
|
Connection Standard |
ISO5211 — PN10/PN16 / 125LB / 150LB / JIS5K / JIS10K / JIS16K |
|
Suited Medium |
Water, gas, oil, treated glycol mixtures |
|
Temperature Range |
0°C – 80°C |
|
Body Material |
Ductile Iron (DI / QT450) |
|
Disc Material |
DI / CF8 (SS304) / CF8M (SS316) / Aluminum Bronze |
|
Seat Material |
EPDM / NBR / PTFE / VITON |
|
Operation Options |
Hand lever, worm gear, pneumatic actuator, electric actuator |
Disk and seat materials of construction are critical to valve service life and maintenance intervals in chilled water operation.
Disk options: CF8 (SS304) and CF8M (SS316) stainless steel resists corrosion from treated water and glycol additions. Aluminum bronze gives further resilience to systems using harsh algicide treatment. Ductile iron disks are a possibility for clean water applications when material cost is a consideration.
Seat options: Standard for closed loop chilled water is EPDM. EPDM treated with peroxide has superior resistance to ozone exposure, heat aging and the corrosion inhibitors often used in chiller systems than NBR. PTFE and VITON seats are offered for Oil or Chemical media.
Disk and stem faces may be rubber lined NBR or EPDM. This protects the metal substrate from erosion and corrosion during long water usage.

The valve body, rotating shaft, disc, seat, and drive mechanism work together to open, close, or throttle flow through a 90° rotation. For chilled water and HVAC cooling applications, the following design points are relevant to butterfly valve for chilled water system performance:
· Low working torque – Reduces actuator size requirements in Building Management System (BMS) applications
· Tight shutdown - Eliminates cold water bypass which compromises Delta-T efficiency in chiller circuits.
• Compact wafer body – Fits between standard flanges without requiring extra space in compact mechanical rooms
· Bi-directional flow – Concentric resilient-seated design permits flow in either direction
• Continuous cycle design - Perfect for repetitive open/close action in HVAC duties
• 90° quarter-turn action for quick response to thermal load control in data center and district cooling applications

A butterfly valve for chilled water system fits across a broad range of cooling infrastructure types.
Data Center Cooling Loops: These valves pair with electric actuators to divert flow for thermal load variations. The seat liner remains intact so that there are no leaks near critical electronics.
District Cooling Networks: In the principal transmission lines, larger diameters (DN600 and higher) manage hydraulic pressure and treated water with algicide. Wafer type installation offers a small pipe arrangement.
High-Rise HVAC Mechanical Rooms: The low-torque design, installed at riser isolation points and AHU connections, minimizes actuator energy consumption in the building management system.
Industrial Water Systems: Also used in petrochemical, power generation and water treatment when the media are fresh water, sewage, saltwater or mild chemical solutions.

The pressure test is performed according to API 598 / EN 12266. Shell tests at 1.5 times the rated pressure confirm the integrity of the body. Seat tests at 1.1x rated pressure validate cutoff function. A low pressure air test is used to evaluate the EPDM liner for micro-porosity.
Coating verification: External body is coated with Fusion Bonded Epoxy (FBE). The inspectors measure thickness using magnetic gages . In mechanical rooms where condensation is a problem , they go for at least 250 microns to resist exterior rust .
Spark testing High voltage spark testing of disk liner and interior coating for pinholes to avoid galvanic corrosion between iron body and system fluid.
Stem seal inspection: Stem O-ring assembly is inspected to ensure it seals out moisture during condensation cycles to safeguard gear operators and actuators from moisture damage.
OEM / ODM manufacture supported by ZTVK. Valves may be provided with your brand name, custom logo, nameplate and packaging.
The engineering team may adapt the valve body structure, sealing material, connection type and pressure or temperature rating to meet project specific needs. Available in wafer, flange and lug type variants.
For purchasers in humid environment, anti-corrosion treatment epoxy resin is optional. Stem protection may also be selected for high-dust conditions.
Available in standard diameters DN50 to DN600. Standard orders ship in 3-7 days. Custom manufacturing lead time is 15-25 days , rush alternatives available in 7-10 days .

Each valve ships in a wooden crate with moisture-proof film and internal fixing brackets. Export packaging meets ISPM 15 phytosanitary requirements.
ZTVK's factory is approximately 50 km from Tianjin Port, roughly one hour by road. FOB Tianjin Xingang and CIF destination-port quotations are both available.
Q1: Why should a system have a long neck?
A: Chilled water pipe normally needs 50-100 mm of insulation to avoid condensation and energy loss. Once you add insulation, a typical valve neck is no longer accessible. The handle or actuator is completely accessible during operation and maintenance since the insulating layer is removed by an elongated neck.
Q2: Should I use EPDM or NBR seat material for chilled water?
A: EPDM is the right material for closed loop chilled water. NBR is suitable for oil service, but degrades more quickly when exposed to the glycol mixes, corrosion inhibitors, and heat cycling found in chiller systems. In these settings peroxide-cured EPDM is more resistant in the long run.
Q3: What is the real difference between wafer and lug type in cooling applications?
A: Wafer valves are installed between two flanges. They are cheaper cost, less weight and good for most isolation applications. Lug valves are designed for dead-end usage and feature threaded inserts that attach to a single pipe flange. This is important for chiller isolation during maintenance, because it enables downstream pipe to be isolated without emptying the whole chilled water loop.
Q4: Will this valve minimize water hammer in cooling loops?
A: Rapid closure is one reason . The valve itself does not reduce water hammer . The valve may be paired with a gear operator or slow-closing electric actuator to regulate the closing rate and prevent pressure spikes in the system.
Q5: Is the flow direction of the installation relevant for this valve?
A: Concentric resilient seated butterfly valves are bi-directional and will allow flow from either direction. Double offset designs used in high pressure risers should be installed in the desired flow direction indicated on the valve body for complete pressure-energized sealing.
Q6: What is the after sales assistance ZTVK provides?
A: Each valve comes with an 18 month guarantee against failure not caused by humans with free replacement. ZTVK also offers installation instructions, troubleshooting literature, CAD drawings and 3D models. The QR code on the product takes you straight to the related inspection report and service history.
Have a butterfly valve for chilled water system requirement or need help selecting the right valve? Contact our team at ktec86961886@163.com for technical support, product selection, or a custom quote.
Send us your valve requirements and our team will provide professional solutions and fast quotations.