ZTVK FLUID CONTROL EQUIPMENT (TIANJIN) CO., LTD. manufactures a butterfly valve with solenoid actuator that combines a quarter-turn butterfly valve with a pneumatic actuator piloted by a solenoid valve. Controls are 24VDC, 120VAC or 220VAC signals. Sizes are from 2″ to 60″ (DN50–DN1500), operating pressure PN10/PN16 and medium water, gas and oil at 0°C–80°C. OUR PRODUCTS ARE MANUFACTURED ACCORDING TO ISO, API, ANSI, DIN AND CE STANDARDS.
A butterfly valve with solenoid actuator is an electromechanical flow control assembly. It uses compressed air directed by a solenoid valve (typically Namur standard) to rotate the butterfly disc 0°–90°, opening or closing the pipeline upon receiving an electrical signal.
The assembly has three working functions:
·Cut-off: Opens or shuts the flow path entirely
· Flow regulation: Controls flow, pressure, temperature or liquid level
· Automated control: Integration with PLC/SCADA systems reduces the need for human intervention
This makes the design ideal for hazardous sites where manual valve operation is not possible, for emergency shut-down (ESD) systems where a rapid reaction is required and for processes that need automation integration.

|
Parameter |
Details |
|
Body Materials |
Ductile Iron (DI), WCB, CF8, CF8M, CF3M |
|
Disc Materials |
SS304, SS316, SS316L |
|
Seat Materials |
NBR, EPDM, VITON, PTFE |
|
Stem Materials |
Stainless Steel 410 / 416 |
|
Body Style |
Flanged Wafer |
|
Size Range |
2″ – 60″ (DN50 – DN1500 mm) |
|
End Connections |
PN10, PN16, 5K, 10K, 16K, 150LB |
|
Working Pressure |
PN10 / PN16 |
|
Working Temperature |
0°C – 80°C |
|
Suitable Media |
Water, Gas, Oil |
|
Pneumatic Actuator |
Double-acting / Single-acting (spring return) |
|
Accessories |
Solenoid valve, limit switch box, filter, E/P positioner, hand wheel |
|
Standards |
ISO, API, ANSI, JIS, BS, DIN, CE |
Types of Actuator – Double Acting and Single Acting
Single acting (spring return) actuators shut or open automatically on loss of air supply, giving a built in fail-safe state. Double acting actuators preserve their previous position when air is shut off, is well suited to situations where holding position is desired.
Both versions comply with the NAMUR VDI/VDE 3845 interface for direct mounting, ensuring compact construction and ease of installation.
Material Choice for Your Application
For harsh chemical media in batch processing loops PTFE seats are used. EPDM seats are good for water treatment applications. CF8M Stainless steel housings with SS316L diaphragms are chemically compatible in corrosive or high purity situations.
Fast Response and Long Life Cycle
Solenoids commonly open/close in under 1 second. The solenoid pilot operates for more than 1 million cycles and the whole valve assembly is rated for more than 50,000 working cycles, providing a viable solution for high frequency switching applications.
IP65/IP67 & NEMA 4X Enclosures
Solenoid coils are IP65/IP67 or NEMA 4X rated and Class H insulated for continuous duty cycle (100% ED) operation.

Desalination & Water Treatment
Proper timing is required in Reverse Osmosis (RO) skids for fast cycling backwash sequences. This requirement is met by solenoid-actuated automation when human operation is not possible.
Chemical Processing
Dosing and fill loops with preset volumetric cut-offs avoid batch mistakes or overflow. We provide PTFE-lined bodies with explosion-proof (ATEX/IECEx) solenoids.
HVAC & District Cooling
For large diameter chiller isolation lines, a fail closed position may be established for power outages that limit uncontrolled pressure fluctuations in downstream equipment.
Metallurgy, Power Generation & Petrochemical
These sectors are offered by ZTVK with designs unique to the media compatibility, pressure class and actuator configuration requirements.

Each assembly is subjected to a tiered inspection procedure before shipment:
1. Hydrostatic & Pneumatic Pressure Test according to API 598 or EN 12266-1, tested at rated pressure
2. Actuator Torque Verification – Output torque verified against break-out torque at a minimum 1.25x safety factor
3. Solenoid Insulation & Heat Rise Testing – verifies 100% duty cycle performance
4. Response Time Analysis - confirms if the speed of opening/closing is within the range set with solenoid energized
5. Dimensional Accuracy Check — Confirmed ISO 5211 mounting pad and Namur interface for accurate component fit
ZTVK supports full OEM and ODM services for this butterfly valve with solenoid actuator line. Available options include:
· Custom logos, branding and nameplates
· Type of valve body construction and connection (flanged, wafer, lug)
· Selection of sealing material compatible with the media
· Solenoid Voltage & Duty Cycle Requirements
· Solenoid explosion-proof (ATEX/IECEx) for dangerous areas
• Local modifications like extra thick protection on the stems for dusty areas or epoxy resin covering for humid areas
Standard sizes of valves DN50–DN600 are stocked (2,000+ units), delivered in 3–7 days. We usually need 15-25 days to produce a custom order, but may rush it in 7-10 days.

ZTVK's factory is approximately 50 km from Tianjin Port, about 1 hour by road. FOB Tianjin Xingang and CIF destination-port pricing are both available.
Export packaging includes wooden crates, moisture-proof film, and fixing brackets following ISPM 15 requirements for long-distance shipping.
All goods have 18 months warranty. Free replacement components for faults not caused by humans. Technical assistance includes:
· CAD drawings and 3D models for pre-planning installation
· Installation video guides and troubleshooting guides
• Access to product information, inspection reports and maintenance histories via QR codes
• Technical assistance onsite by local service partners

Q1: Can the fail safe location be configured on site?
A: For 5/2-way Namur solenoids working with double-acting actuators, the fail logic may be reversed by reversing the pneumatic tubing or by turning the Namur plate 180°. The fail position for spring return actuators is in the direction of the spring. The solenoid logic (Normally Open or Normally Closed) may typically be altered at the solenoid level.
Q2: How to avoid solenoid coil overheating in 24/7 operation?
A: Select a solenoid coil rated at 100% Duty Cycle. Low Wattage Coils (2.5w or less) Reduce heat output when used continuously.
Q3: What is the actuator air supply pressure?
A: The normal range is 4–8 bar (60–120 PSI). Torque production decreases below 4 bar and the valve may stall mid stroke. We strongly suggest installing a regulator upstream of the actuator.
Q4: Is this assembly designed for vacuum service?
A: The butterfly valve uses bonded liners, rated for vacuum service. The solenoid actuator is operated with positive compressed air independent of the vacuum pipeline state which calls for careful checking of the stem packing to avoid the intrusion of air.
Q5: Why the valve closes suddenly, and water hammer?
A: Fast closure due to the rapid solenoid exhaust. Installation of flow control silencers on the solenoid exhaust ports helps to reduce the air release rate and delay the closing stroke of the butterfly valve; this reduces hydraulic shock.