ZTVK FLUID CONTROL EQUIPMENT (TIANJIN) CO., LTD. manufactures butterfly valve pneumatic actuators for industrial automation pipelines. Available in diameters from DN40 to DN1200 (1.5″–48″), rated at PN10/PN16, these devices are designed to handle water, gas, oil and air from 0 °C to 80 °C. Rack and pinion system provides a uniform output torque across the whole 0° to 90° stroke. The body materials include aluminum, cast iron, stainless steel and WCB carbon steel. It supports flanged and wafer end connections.
Compressed air is stored in the actuator body to drive a rack and pinion mechanism to rotate the valve stem and butterfly disk along a 0°-90° arc to open or shut the flow stream. There are two configurations:
· Double-Acting: Both the opening and closing strokes are powered by air pressure. If the air supply is disconnected, the disk remains in its previous position.
· Single-acting (spring return): Air flows in one direction; internal springs return the disk to a pre-set fail-safe position — typically open or normally closed — when air pressure is lost. Hence it is the option for emergency shut-down loops [1].
Both designs may be linked to a solenoid valve and integrated into a PLC or DCS control system, so there is no need for human on-site operation in dangerous or inaccessible places.

|
Parameter |
Details |
|
Size Range |
DN40–DN1200 (1.5″–48″) |
|
Working Pressure |
PN10 / PN16 (10/16 bar) |
|
Actuator Type |
Rack & Pinion |
|
End Connection |
Flanged / Wafer |
|
Suitable Media |
Water, Gas, Oil, Air |
|
Media Temperature |
0 °C – 80 °C |
|
Body Materials |
Aluminium, Cast Iron, Stainless Steel, WCB Carbon Steel |
|
Accessories |
Air Filter Regulator, Solenoid Valve, Limit Switch Box, Proximity Switch Box |
|
Mounting Interface |
ISO 5211 / NAMUR (VDI/VDE 3845) |
|
Applicable Standards |
ISO, API, ANSI, DIN, JIS, BS, CE |
Rack and pinion steering.The rack and pinion arrangement has a consistent output torque across the whole stroke, unlike scotch yoke methods, which makes actuator sizing easier for common on/off applications.
NAMUR and ISO 5211 mounting pad.NAMUR-standard ports (VDI/VDE 3845) enable solenoid valves, limit switches and positioners to be mounted directly on the actuator without the need for extra brackets. The flange designs according to ISO 5211 allow direct valve to actuator connections, between valves of compatible manufacturers.
Flow modulation capabilitiesIf throttling rather than basic on/off control is required, an electro-pneumatic positioner that accepts a 4–20 mA signal may be fitted. This enables the disk to halt at exact intermediate angles, e.g. 45°, to control flow, pressure or liquid level.
Material possibilities for various contexts.The aluminum body units are hard-anodized for corrosion and wear protection. Stainless steel 316 bodies are provided for sanitary processing or offshore conditions where increased corrosion resistance is required.

· Petrochemical and oil refining — Spring-return actuators are suited for emergency shut-down (ESD) loops, moving the valve to a safe position automatically when air supply fails.
· Water treatment and desalination — Large-bore butterfly valve pneumatic actuator units manage intake and discharge flows where corrosion resistance and cycle reliability matter.
· Food and beverage processing — Stainless steel actuators with sanitary butterfly valves facilitate CIP (clean-in-place) rapid-cycle cleaning sequences.
· Power generation, metallurgy and natural gas distribution – High cycle automation applications where constant torque production and extended service life are critical.
· Pharmaceuticals and chemical processes – Body and seal materials may be customized for harsh or purity-sensitive media as per project specifications.

Each product is inspected by the following processes before shipping:
· Shell and seal leakage test – According to EN 15714-3 at 1.1× nominal pressure; neither internal nor exterior air leakage is permitted.
· Output torque test — The output torque is evaluated on a calibrated bench at certain air supply pressures with a target safety margin of 1.3×–1.5× above the valve’s breakout torque.
· Salt spray test (ASTM B117) - Anodized and coated items are tested for 500 to 1000 hours with no red rust development allowed.
· Cycle life test – Sample units under load are cycled open/close many times to assess rack, pinion and spring fatigue performance.
Inspection records are accessible for the consumer to inspect, upon request.

ZTVK accepts both OEM and ODM orders for the butterfly valve pneumatic actuator range.
OEM work involves bespoke branding, nameplates, logos and export packing as per distributor specifications. ODM work involves the adaption of the actuator-to-valve interface, choice of sealing materials for appropriate media and configuration for wafer, flanged or lug end connections.
Standard DN50-DN600 units are in stock, shipping in 3-7 days. Standard manufacturing time for custom orders is 15-25 days. Expedited production time may be achieved in 7-10 days if schedule permits.
The site is around 50km from Tianjin Port (almost one hour by vehicle). FOB Tianjin Xingang and CIF destination-port prices are available. The goods are packed in hardwood containers with moisture-proof film and attaching brackets according to ISPM 15.

Q: What is the difference between a double acting and spring return actuator?
A: Double-acting needs air for opening and air for closing. Spring-return valves employ air to actuate in one direction and mechanical springs for the return stroke. This gives the valve a specified fail-safe position in case of loss of air pressure.
Q: How do I select the correct actuator size?
A: Start with the maximum needed torque of the valve (including seating and unseating torque) and choose an actuator with a rated output at your minimum supply pressure that is 25%–30% higher than that number. This space allows for seat swelling or accumulation of media in service.
Q: Can this actuator be used for throttling control and not just on/off?
A: Yeah. An electro-pneumatic positioner with a 4–20 mA input enables the disk to maintain any intermediate angle for flow modulation.
Q: What is the recommended quality of compressed air?
A: It must be provided with dry, clean air. ISO 8573-1 Class 4 is a good reference point. Moisture or particles in the air supply may harm the O-rings and cylinder walls over time.
Q: Water hammer caused by rapid shutting of valve. What do I do?
A: Install exhaust flow control mufflers (speed controllers) in the actuator ports. The closing stroke is slowed and pressure spikes in the pipeline are reduced by restricting the exhaust flow rate.
Q: What is the after-sales service?
A: 18-month guarantee against non-human causes for product failures, free replacement. Installation support, troubleshooting documents and inspection records are provided.
Request butterfly valve pneumatic actuator pricing, technical datasheets, or a custom configuration quote at ktec86961886@163.com — we will respond within one business day.
Send us your valve requirements and our team will provide professional solutions and fast quotations.