thumbnail
solenoid operated butterfly valve
/ Pneumatic Butterfly Valve

solenoid operated butterfly valve

Operated: Pneumatic actuator
Connection method:Wafer type
Connection standard:ISO5211--PN10/PN16/125LB/150LB/JIS5K/JIS10K/JIS16K
Size:1.5"-48"(DN40-DN1200 mm)
Working pressure:PN10/PN16
Body material:DI/QT450
Disc material:DI/CF8/CF8M/Aluminum bronze
Seat material:EPDM/NBR/PTFE/VITON/
Product Description

Solenoid Operated Butterfly Valve | Pneumatic Actuated Wafer Type | DN40–DN1200

ZTVK manufactures valves in Tianjin, China, and this quarter-turn wafer valve is one of the more frequently specified products in the range. The assembly combines a pneumatic actuator with an electric solenoid pilot — the result is a solenoid operated butterfly valve that handles automated flow control across DN40–DN1200 (1.5"–48"). The operating pressure is PN10/PN16, the temperature range is 0°C to 80°C, and the disk possibilities are DI, CF8, CF8M or aluminum bronze and the seat options are EPDM, NBR, PTFE or VITON.

What Is a Solenoid Operated Butterfly Valve?

A solenoid operated butterfly valve pairs a butterfly valve body with a pneumatic actuator and an electric solenoid pilot valve. When an electrical signal (usually 24VDC, 110VAC or 220VAC) is sent to the solenoid, it directs compressed air to spin the disk 0° to 90°, opening or shutting the flow route.

This setup is ideal for remote operation, emergency shutdown (ESD) systems and connection with SCADA or PLC control platforms when human intervention is impracticable or process timeliness is crucial.

factory

Key Features and Design Notes

Double-eccentric structure inclined sealing design

The shape minimizes operating torque compared to normal center-line butterfly valves, therefore reducing wear on the seat and disk during repeated cycling.

Single & Double Acting Actuator Alternatives

Single acting (spring return) offers the advantage of a specified fail-safe position, the valve will go to its spring-set position if air supply is interrupted. If air is lost, the double-acting stays remain in its previous position, which is fine for stable systems where no permanent fail-safe is needed.

Mounting interface ISO 5211

The NAMUR-standard solenoid interface connects directly to pneumatic actuators without the need for extra adapters, simplifying installation.

Ingress protection IP65 / IP67 optional

Solenoid coils are available in explosion-proof configurations (NEMA 7/9, ATEX) appropriate for petrochemical, gas distribution and hazardous area applications.

Technical Specifications

Parameter

Details

Actuation Type

Pneumatic actuator with solenoid pilot valve

Connection Method

Wafer type

Connection Standard

ISO 5211 — PN10/PN16/125LB/150LB/JIS5K/JIS10K/JIS16K

Size Range

1.5"–48" (DN40–DN1200)

Working Pressure

PN10 / PN16

Temperature Range

0°C – 80°C

Body Material

DI / QT450 (Ductile Iron)

Disc Material

DI / CF8 / CF8M / Aluminum Bronze

Seat Material

EPDM / NBR / PTFE / VITON

Suitable Media

Water, gas, oil, and other compatible fluids

Certificates

Application Industries

Sewage Treatment.

This valve is often specified for large volume flow with suspended particles in automated aeration and sludge treatment systems. The butterfly disk shape is less subject to clogging than globe type valves under these settings.

Chemical Processing & Petrochemicals

ESD applications may choose between PTFE seat liner or CF8M stainless steel disk choices for chemical resistance. The spring return arrangement will restore the valve to its fail safe position upon a power failure or an alert.

Industrial Chiller and HVAC Systems

Building Management System (BMS) integration of solenoid actuation of large-diameter condenser water loops allows flow to be adjusted in real-time depending on thermal demand.

This valve is also utilized in industries such as power production, metallurgy, natural gas distribution, pharmaceutical and food processing.

Packaging and Shipping

Quality Control

Before shipping ZTVK uses the following inspection protocols:

Hydrostatic Pressure Test (API 598) The valve body is tested at 1.5x rated pressure for shell integrity. The seat is tested at 1.1× rated pressure to check the shutdown characteristics.

Cycle Endurance Testing: assemblies are cycled open/closed. This technique verifies the temperature of the solenoid coil and the integrity of the actuator seal.

Positive Material Identification (PMI) XRF analysis is used to verify the alloy composition of the disk and stem.

Response Time Verification – The time from energizing the solenoid until the disk has traveled the entire 90° distance is measured and recorded.

The organization is certified ISO 9001, ISO 14001 and OHSAS 18001. Third party factory inspection is supported and certification documentation may be obtained on request.

Use Cases

OEM and ODM Customization

ZTVK supports OEM and ODM:

We provide OEM service including logo, nameplate, brand and export packing.

ODM services include valve body structure redesign, sealing material selection, connection configuration adjustment, and adaption to specified pressure, temperature and media conditions.

Standard solenoid operated butterfly valve ship within 3–7 days. Custom production runs 15–25 days, with an expedited path of 7–10 days for qualifying urgent orders.

Packaging and Logistics

Export packaging uses wooden crates, moisture-proof film, and fixing brackets, all compliant with ISPM 15 international phytosanitary standards.

The ZTVK factory is approximately 50 km from Tianjin Port, with an estimated road time of one hour. FOB Tianjin Xingang and CIF destination-port quotations are both available.

Exhibitions

FAQ

Q1: What is the difference between single-acting and double-acting designs?

A: Single-acting (spring return) utilizes air to move in one direction and a spring to return on lack of power or air, this creates a specified fail safe position. Double acting . You need air in both directions . It gives you fine control , but no automated fail-safe till you have a backup air reservoir .

Q2: Is it possible to mount the valve in the vertical position with the shaft?

A: Preferred Practice Installation of Horizontal Shaft. This helps to stop debris building up at the bottom shaft bearing and lowers side-loading on the actuator, therefore increasing seal life.

Q3: Why is the solenoid buzzing or heating up?

A: Common reasons include low supply voltage, dirt preventing the armature from sitting, or improper voltage provided to the coil. Check coil and air gap immediately to prevent burn out.

Q4: How to lessen the water hammer while the valve is closing quickly?

A: Throttle fittings or exhaust speed control mufflers may be installed on the exhaust ports of the pneumatic actuator to decrease the spinning of the disk and to minimize the pressure spikes in the pipeline.

Q5: What is regular maintenance on this valve?

A: Check the compressed air supply periodically for moisture. Water in the air stream might harm solenoid coils. Check seats for wear and service flange bolts on a timetable. If the valve is generally idle, cycle it at least monthly to prevent the seat from adhering to the disk.

Q6: For what media is this valve appropriate?

A: The valve is suitable for water, gas, oil and other compatible fluids in 0°C to 80°C temperature range. The seat material is made of EPDM, NBR, PTFE or VITON, which should be chosen according to the medium and the temperature.

Contact Us

Send your inquiry or solenoid operated butterfly valve quote request to ktec86961886@163.com. We respond to technical and commercial questions within one business day.

Online Message