

The 2 inch silent check valve from ZTVK FLUID CONTROL EQUIPMENT (TIANJIN) CO., LTD is a spring-loaded, non-return flow control device designed to eliminate water hammer and hydraulic shock in DN50 piping systems. The valve has both a "bullet head" disk profile and a "waist drum" body shape. These shapes are meant to make the flow direction smooth and lower the resistance. Its flanged ductile iron construction makes it useful for water supply, drainage, and high-rise building distribution networks. It can handle nominal sizes from DN15 to DN500 at PN16.
A 2 inch silent check valve is a non-return device rated at NPS 2" (DN50). Unlike traditional swing check valves — which rely on gravity and reverse flow to close, often producing a loud pressure slam — this valve uses a spring-loaded disc that closes at the moment flow velocity reaches zero, before any reversal occurs.
By getting rid of that reverse, the pressure spikes called "water hammer" are stopped, which can damage lines and wear out pumps over time. In situations where both noise level and long-term pipe integrity are important, a spring-loaded silent check valve can solve both problems.

Bullet head disk and waist drum body
The disk has a "bullet head" shape that is round, and the body is cast in a "waist drum" shape. When compared to straight-bore body designs, they lower the overall flow resistance coefficient, make the flow path smoother, and lower the amount of turbulence.
lubrication cover made of non-metal
Between the guide shaft and the guide frame is a sleeve that is not made of metal. It keeps the disk going easily through its full stroke, even after a lot of service rounds.
frame-type rubber closing ring built into the body of the valve
The closing ring is built right into the valve body, so it doesn't have to deal with constant straight flow. This keeps the rubber from wearing away over time and helps the seal work better over time.
Short strokes to open and close
Between the open and closed positions, the disk moves only a short distance. If the valve responds faster, it can stop the flow of reverse before pressure waves can reach the rest of the system.
Small body shape
The valve is light and easy to fit into tight pipe spaces because its body is short. When planning for low-pressure drop uses, it's important to keep in mind that this type of check valve loses a little more water head than lift-type quiet check valves.

|
Parameter |
Details |
|
Nominal Size |
DN15 – DN500 (2 inch = DN50) |
|
Nominal Pressure |
PN16 |
|
Connection Type |
Flanged |
|
Body Material |
Ductile Iron |
|
Disc Shape |
Bullet Head Profile |
|
Body Shape |
Waist Drum Profile |
|
Seal Type |
Frame-type rubber sealing ring |
|
Guide Sleeve Material |
Non-metallic lubricating sleeve |
|
Suitable Media |
Clean water (not sewage or particulate-laden fluids) |
|
Applicable Standards |
ISO, API 598, MSS SP-125 |
|
Shell Test Pressure |
1.5× rated working pressure |
|
Seat Leakage Test |
1.1× rated pressure / low-pressure air |
Water supply and drainage systems
Standard building water supply lines and drainage networks require reliable one-directional flow. The flanged ductile iron body handles the pressure and cycle loads typical of municipal and commercial building service.
High-rise building water distribution networks
In tall structures, pump discharge noise can travel through steel risers and affect occupied floors. Installing a 2 inch silent check valve on pump discharge lines stops the slam noise at its source, protecting both pipework and building occupants.
Setting up the pump outlet
For straight placement at a pump exit, the valve is the right size and shape. The disk shuts with a spring before backflow can reach the propeller when the pump stops. The valve can also be used as a pressure bottom valve with some slight changes to its structure.
HVAC branch lines for cold water
When chiller systems change the pressure quickly, it can put stress on pipe joints and fittings. A silent check valve on 2-inch branch lines lowers hydraulic shock and speeds up the wear process at connection points.
Note: This valve shouldn't be used in sewer pipes or any other medium that has solid bits or fluids with a high viscosity. For a list of approved media, see the table of specifications above.

Test of the hydrostatic shell
To make sure the case is solid and to look for holes in the ductile iron casting, the valve body is pressed up to 1.5 times its maximum working pressure.
Test for seat leakage
At 1.1 times the maximum pressure or with low-pressure air, testing is done. There can be no leakage in resilient-seated valves. API 598 allows certain leaking rates to be checked against metal-seated valves.
Checking for spring compression
To make sure the disk shuts all the way at zero flow rate, the spring constant is checked. If the spring is too weak, the disk can act like a swing check valve, which takes away from the valve's ability to stop water hammer.
Tracking of materials
Mill Test Reports are looked over to make sure that the chemical make-up of body materials is the same as the required ductile iron grade.
ZTVK is certified by ISO 9001, ISO 14001, and ISO 45001 standards. During third-party factory inspections, certification documents can be looked over.
ZTVK supports both OEM and ODM orders across the silent check valve range.
· OEM: Custom branding, logo, nameplate, and export packaging
· ODM: Sealing material selection (EPDM, Buna-N, or Viton), connection configuration, pressure and temperature adaptation, body material changes (carbon steel WCB, SS304/316, duplex steel)
Standard DN50–DN600 valves are held in stock at 2,000+ units, available for prompt shipment. Custom orders are typically completed in 15–25 days, with expedited production options for urgent requirements at 7–10 days. The factory is located approximately 50 km from Tianjin Port, and both FOB Tianjin Xingang and CIF destination-port pricing are available. Export packaging uses wooden crates, moisture-proof film, and fixing brackets per ISPM 15 requirements.

· Pre-sales: Valve selection guidance, CAD drawings, 3D models, and technical consultation
· After-sales: 18-month warranty; free replacement for failures not caused by misuse or improper installation
· Installation support: Guidance videos, troubleshooting manuals, and access to local technical service partners
· Digital records: Scan the product QR code to access inspection reports, maintenance records, and product history

Q1: What's the main difference between a swing check valve and a silent check valve?
A: A swing check valve usually makes a pressure slam when it stops because of gravity and backward flow. A quiet check valve has a disk that stops at zero speed, before the flow goes the other way, so there is no slam and no water hammer.
Q2: Can this valve be put in place vertically?
A: Yes. When there is vertical-up flow, like when a pump discharge line feeds an elevated storage tank, the spring-loaded disk closes correctly.
Q3: What kinds of sealants are there?
A: The normal form has a frame-type rubber closing ring built into the body of the valve. EPDM, Buna-N, and Viton elastomers can be used in situations where they need to be resistant to certain chemicals or temperatures.
Q4: Can this valve be used on sewage pipes?
A: Not really. The valve shouldn't be used with sewage or any other liquid or media that contain solid particles. These situations can hurt the sealing ring and make it impossible for the disk to move.
Q5: What tests does each valve go through before it is shipped?
A: Every unit is checked for seat leaks at 1.1× rated pressure, hydraulic shell integrity at 1.5× rated pressure, and zero-velocity closing by compressing the spring. It is also confirmed that materials can be tracked using Mill Test Reports.
Q6: Do you offer custom sizes or configurations that aren't standard?
A: Yes, ZTVK allows ODM customization for the material of the body, the material used for closing, the type of link, and the pressure grade. Standard wait time for special items is 15–25 days, but you can get them faster in 7–10 days.
Request a quote, technical drawing, or 2 inch silent check valve sample for your project. Email our team at ktec86961886@163.com — we respond within one business day.
Send us your valve requirements and our team will provide professional solutions and fast quotations.